Revision 1.3 Page i ®® TLM100 Tank Level Monitor User’s Manual Revision 1.3 Copyright © 2010 Maretron, LLP All Right
TLM100 User’s Manual TLM100 Sensor Component TLM100 Interface Component SAE 5-Bolt Tank Fitting TLM100 Gasket Mounting Screws (x5) Figure 2 – TL
®®Focus Tube Gasket Focus Tube TLM100 Gasket TLM100 Sensor Component Mounting Screws (x5) SAE 5-Bolt Tank Fitting TLM100 Interface Component 1” (2.
TLM100 User’s Manual TLM100 Interface Component Threaded Tank Fitting Threaded Adapter TLM100 Gasket TLM100 Sensor Component Mounting Screws (x5)
®®1” (2.54cm) clearance between focus tube and tank bottom TLM100 Interface Component Threaded Tank Fitting Threaded Focus Tube TLM100 Gasket TLM10
TLM100 User’s Manual 2.5 Connecting the TLM100 There is one connection point (see Figure 6) for the TLM100: the NMEA 2000® connection. Please refe
Revision 1.3 Page 11 ®®3 Configuring the TLM100 The TLM100 has several configurable parameters, which are shown below including the default
TLM100 User’s Manual Page 12 Revision 1.3 software. Refer to the user’s manual of the particular product that will be used for configuring
Revision 1.3 Page 13 ®®Symptom Troubleshooting Procedure No tank level output 1. If operating in the NMEA 2000® Mode, check the connection
TLM100 User’s Manual Page 14 Revision 1.3 6 Technical Specifications Specifications Parameter Value Comment Accuracy ±2% Resolution ±1
Revision 1.3 Page 15 ®®Mechanical Parameter Value Comment Size 3.9”” x 1.2” x 1.0” (99mm x 30.5mm x 25.4mm) Interface Component 2.7” dia
TLM100 User’s Manual Page ii Revision 1.3 Revision History Revision Description 1.0 Original document 1.1 Corrected typo in NMEA protoco
TLM100 User’s Manual Page 16 Revision 1.3 8 Maretron (2 Year) Limited Warranty Maretron warrants the TLM100 to be free from defects in m
Revision 1.3 Appendix A – NMEA 2000® Interfacing Page A1 ®®Appendix A – NMEA 2000® Interfacing TLM100 NMEA 2000® Periodic Data Transmitted PG
Revision 1.3 Page iii ®®Table of Contents 1 General ...
TLM100 User’s Manual Page iv Revision 1.3 Table of Figures Figure 1 - TLM100 Operation ...
Revision 1.3 Page 1 ®®1 General 1.1 Introduction Congratulations on your purchase of the Maretron Tank Level Monitor (TLM100). Maretron has
TLM100 User’s Manual Page 2 Revision 1.3 1.5 TLM100 Accessories Maretron offers the following accessories for the TLM100: • TA-5H-1.5NP
®®then be received back at the sensor component. Using the speed of sound, it uses this time to calculate the distance between the face of the senso
TLM100 User’s Manual Page 4 Revision 1.3 • The sensor component of the TLM100 must be mounted over the deepest part of the tank, in order
®®2.4 Mounting the TLM100 2.4.1 Mounting the TLM100 Sensor Component The TLM100 comes from the factory ready to mount on a tank with the standard S