Revision 1.4.2 Page i ®® DSM250 NMEA 2000® Multi-function Color Graphic Display User’s Manual Revision 1.4.2 Copyright ©
DSM250 User’s Manual Page x Revision 1.4.2 Figure 47 – Current Sensor Zero Offset Calibration Confirmation Screen ...
DSM250 User’s Manual 6.10.1.2 Installation Description This entry allows you to modify the NMEA 2000 installation description text strings. You
®® Figure 77 – J2K100 NMEA 2000® PGN Enable/Disable Screen You can enable or disable specific transmissions by scrolling ( or ) through the diff
DSM250 User’s Manual Page 88 Revision 1.4.2 Use the Scroll Up and Scroll Down keys to change the value to the desired value you wish to use as
®®6.10.5 Refresh J1939 source address list The configuration screen for the J2K100 will examine the bus to determine to which devices it can conn
DSM250 User’s Manual Use the Scroll Up ( ) or Scroll Down ( ) keys to change the value to the desired value you wish to use as the engine instanc
®®6.11 Maretron RAA100 Configuration This describes the configuration of the Maretron RAA100 firmware version 1.4.9. Maretron RAA100 rudder angl
DSM250 User’s Manual 6.11.1.2 Installation Description This entry allows you to modify the NMEA 2000 installation description text strings. You
®® See section 3.3.4 for details on how to enter a textual value. 6.11.3 Rudder Angle Calibration In order for the RAA100 to indicate an accurat
DSM250 User’s Manual To perform custom calibration of the rudder angle sender, use the Scroll Up ( ) or Scroll Down () keys to move the highlighte
®®the RAA100. Figure 85 shows a screenshot of the center rudder calibration screen. You may also press the Abort Key ( ) to end the calibration pr
®®Revision 1.4.2 Page vi Figure 95 – RIM100 Channel Configuration Screen ...
DSM250 User’s Manual Figure 87 – Custom Rudder Calibration Confirmation Screen 6.11.3.2 Set to American Standard (240-33 ohm) Use the option fo
®® Figure 88 – Setting the Rudder Number 6.11.5 Operating Mode The RAA100 can be operated in one of two operating modes, depending on the install
DSM250 User’s Manual 6.11.6 Gauge Resistance, + to Sender If the desired operating mode is “NMEA 2000 & Analog Gauge”, the two gauge resistan
®® Figure 91 – Setting the – to Sender Gauge Resistance Revision 1.4.2 Page 99
DSM250 User’s Manual 6.12 Maretron RIM100 Configuration This describes the configuration of the Maretron RIM100 firmware version 1.1.1. The DSM2
®®6.12.1.2 Installation Description This entry allows you to modify the NMEA 2000 installation description text strings. You can enter any infor
DSM250 User’s Manual 6.12.3 Instance From here the instance used in the data message may be set. 6.12.4 Channel Configuration To configure an in
®®6.13 Maretron SIM100 Configuration This describes the configuration of the Maretron SIM100 firmware version 1.1.1. The DSM250 may be used to c
DSM250 User’s Manual 6.13.1.2 Installation Description This entry allows you to modify the NMEA 2000 installation description text strings. You
®®6.13.3 Instance From here the instance used in the data message may be set. 6.13.4 Channel Configuration To configure an individual channel, u
DSM250 User’s Manual Page xii Revision 1.4.2 Figure 143 – Intermediate Level Calibration ...
DSM250 User’s Manual 6.14 Maretron SSC200 Configuration This describes the configuration of the Maretron SSC200 firmware version 2.0.11. Nine con
®®6.14.1.2 Installation Description This entry allows you to modify the NMEA 2000 installation description text strings. You can enter any infor
DSM250 User’s Manual The last line in the menu enables you to program the lifetime of the variation data received by the SSC200. In Figure 103, yo
®®6.14.1.4 NMEA2000 PGN Enable/Disable The SSC200 compass transmits several different messages, which can be turned on or turned off by the DSM25
DSM250 User’s Manual Page 110 Revision 1.4.2 Figure 106 –SSC200 Installation Offset Calibration Screen Use the Increase ( ) and Decrease ( )
®®The choices that are offered are “Normal Installation” (default), “Backward Installation”, “Upside-Down Installation”, or “Upside Down and Backw
DSM250 User’s Manual Figure 109 –SSC200 Magnetic Deviation Calibration Progress Screen This progress screen shows the number of circles complete
®® Figure 111 – Programming SSC200 Rate of Turn Damping Period 6.14.8 Rate of Turn Zero Offset Calibration The DSM250 is capable of displaying r
DSM250 User’s Manual information regarding the magnetic variation at the current location is required. Please see the SSC200 User’s Manual for mor
®®Figure 115 below shows the NMEA 2000® source selected. Revision 1.4.2 Page 115 Figure 115 – Setting Variation Source to NMEA 2000® Only If
®®Revision 1.4.2 Page vi Figure 192 – Trigger Configuration Editor - Tripped Alert ...
DSM250 User’s Manual WARNING: Magnetic variation changes as your location on the earth changes; therefore magnetic variation should be adjusted wi
®®6.15 Maretron TLA100 Configuration Maretron TLA100 tank level adapters on the network may be configured using the DSM250. This describes the co
DSM250 User’s Manual 6.15.1.2 Installation Description This entry allows you to modify the NMEA 2000 installation description text strings. You
®®To program the tank capacity, use the Scroll Up ( ) or Scroll Down ( ) keys to move the highlighted cursor over the “Tank Capacity:” menu item.
DSM250 User’s Manual • Custom Calibration – use for non-rectangular tanks or non-standard sensors (also, most accurate in any case, but requires
®® Figure 123 – Tank Levels Calibration Capacity Estimation The next step in the calibration process is to fill the tank and indicate the volume
DSM250 User’s Manual Figure 125 – Intermediate Level Calibration Once the tank is completely full, instead of pressing the Accept key to store t
®® Figure 127 – Custom Tank Level Calibration Confirmation Screen 6.15.4.2 American Standard Sender Calibration If you have a rectangular tank, a
DSM250 User’s Manual Figure 129 – European Standard Sender Calibration 6.15.5 Tank Number Next, the tank number must be configured. A tank numbe
®®keys to position the highlighted cursor over “Tank Type:”, then press the Enter key ( ) to move the highlight to the tank type data itself. Now,
DSM250 User’s Manual Figure 132 – Configuring the Operating Mode 6.15.8 Gauge Resistance, + to Sender If the desired operating mode is “NMEA 200
®®To program the - to sender gauge resistance, use the Scroll Up ( ) or Scroll Down ( ) keys to move the highlighted cursor over the “Gauge Resist
DSM250 User’s Manual 6.16 Maretron TLM100 Configuration The DSM250 may be used to configure and calibrate the Tank Level Monitor (TLM100 / TLM150
®®installed, for later reference. Tools such as Maretron N2KAnalyzer allow you to view these values later. 6.16.1.3 NMEA2000 PGN Enable/Disable
DSM250 User’s Manual change the value to the desired tank capacity value, and finally, press the Accept key to confirm your selection. Figure 13
®®6.16.4.1 Custom Calibration The Custom Calibration setting will provide the most accurate tank level readings under any circumstances, but it r
DSM250 User’s Manual The next step in the calibration process is to fill the tank and indicate the volume of fluid in the tank at various points
®®Once the tank is completely full, instead of pressing the Accept key to store the current calibration point, press the Complete key. This will c
DSM250 User’s Manual Figure 146 – Rectangular Tank Selection The following screen will be displayed. Figure 147- Rectangular Tank Calibration
®®Live Well - Oil - Black Water - Reserved-1..Reserved-7 – These values may be used when the contents of the tank does not fit into one of the
®®Revision 1.4.2 Page 1 1 General 1.1 Introduction Congratulations on your purchase of the Maretron DSM250 NMEA 2000® Multi-function Color Gr
DSM250 User’s Manual 6.19 Maretron TMP100 Configuration Maretron Temperature Modules (TMP100) may be configured using the DSM250. This describes
®®6.19.1.2 Installation Description This entry allows you to modify the NMEA 2000 installation description text strings. You can enter any infor
DSM250 User’s Manual Figure 151 – TMP100 Channel Configuration Screen 6.19.2.1 Instance The Data Instance of the Temperature (as sent in PGNs 13
®®6.20 Maretron USB100 Configuration Maretron USB100 gateways on the network may be configured using the DSM250. This describes the configuration
DSM250 User’s Manual Page 140 Revision 1.4.2 6.20.1.2 Installation Description This entry allows you to modify the NMEA 2000 installation desc
®®are satisfied with the state of the “Display” setting, press the Enter key ( ) to accept the setting. The USB100 will retain information on devi
DSM250 User’s Manual 6.21 Maretron WSO100 Configuration The DSM250 is capable of performing configuration of the WSO100 Wind/Weather Sensor. This
®®6.21.1.2 Instance - Humidity This entry allows you to program the NMEA 2000 device instance for the humidity transmitted in PGN 130313. You us
DSM250 User’s Manual Disable – The message will not be transmitted Default – The message will be transmitted at its default NMEA2000 rate. 0.5s…5
®® Figure 158 – WSO100 Installation Offset Screen Turn the vessel directly into the wind and motor forward. When you are satisfied that the appar
DSM250 User’s Manual Page 2 Revision 1.4.2 2 Installation 2.1 Unpacking the Box When unpacking the box containing the Maretron DSM250, you sh
DSM250 User’s Manual Figure 160 – Installation Offset Success Confirmation Screen Page 146 Revision 1.4.2 You may instead abort calibration b
®® Figure 162 – Setting the Wind Data Damping Period 6.21.5 Barometric Pressure The WSO100 has an internal barometer, which is pre-calibrated bef
DSM250 User’s Manual Figure 164 – Setting the Outside Humidity Use the Increase and Decrease buttons to select the correct humidity, and the pre
®®7 Data Display Types 7.1 Anchor Watch Display The Anchor Watch Display is a graphical representation of an Anchor Alert. See section 8.3.7.9 f
DSM250 User’s Manual Figure 167 – Compass Rose Display (Course Up) Example Figure 168 – Compass Rose (North Up) Display 7.3 Gauge Display The
®® Figure 169 – Gauge Display Example A full-screen example of the rudder gauge display can be seen in Figure 170 below. Figure 170 – Rudder An
DSM250 User’s Manual 7.4 GPS Status Display The GPS Status display shows the following data about the selected GPS receiver: • GPS operating mo
®® Figure 172 – Numeric Display Example Revision 1.4.2 Page 153 The upper left hand corner indicates the parameter being displayed and the cen
DSM250 User’s Manual • SOG (Speed Over Ground) • BTW (Bearing to Waypoint) • DTW (Distance to Waypoint) • VMG (Velocity Made Good) • ETA (Est
®® Figure 175 – Line Graph Display 7.8 Weather Display The DSM250 supports a single-screen weather display that shows a wide variety of weather-r
®®Revision 1.4.2 Page 3 a. Make sure the studs are fully inserted into the back of the DSM250 but don’t over tighten the studs. 6. Insert the
DSM250 User’s Manual • Moon Phase • Sunrise • Sunset 7.9 Wind Rose The DSM250 supports a wind rose display, which displays apparent wind directi
®®7.11 Trim Tab Display The DSM250 supports a trim tab display in which the relative positions of the port and starboard trim tabs are displayed
DSM250 User’s Manual 7.13 Tank Gauge Display The DSM250 supports a tank level gauge display type which shows percentage of fluid remaining in a t
®®8 Alerts The DSM250 can act as both an Alert Source and an Alert Monitor. An Alert Source monitors parameters received on the NMEA2000® bus aga
DSM250 User’s Manual Page 160 Revision 1.4.2 8.2 Accepting or Cancelling an Alert Active Alerts may be accepted (4.3.2) by the operator to in
®® Pressing the Enter button at this point will Accept or Cancel the Alert. 8.3 Adding an Alert Alerts are created by selecting the parameter to
DSM250 User’s Manual Page 162 Revision 1.4.2 Figure 184 – Part of the Alert Edit Screen This allows the entry of all the alert parameters, wh
®®8.3.4 Trigger Source This allows the selection of the parameter to be monitored. The parameters are laid out as per section 4.2. The trigger sou
DSM250 User’s Manual Page 164 Revision 1.4.2 Figure 185 – High Alert Parameters A high alert is triggered (i.e. becomes an active alert) once
®® Figure 186 – Trigger Configuration – High Alert Re-trigger Period – When you accept an alert, it will change to the “Accepted” state, and annu
DSM250 User’s Manual Page 4 Revision 1.4.2 a. Place your thumbs on top of the studs and your finger along the side of the case and squeeze the
DSM250 User’s Manual Page 166 Revision 1.4.2 Figure 187 – Low Alert Parameters A low alert is triggered (i.e. becomes an active alert) once a
®®8.3.7.2.2 Trigger Configuration Figure 188 - Trigger Configuration – Low Alert Re-trigger Period – When you accept an alert, it will change
DSM250 User’s Manual Water Temperature parameter, you would then get an alert every time the ignition was switched off and the engine’s ECU stoppe
®® Figure 190 – Trigger Configuration – On Alert Accept Re-trigger Period – When you accept an alert, it will change to the “Accepted” state, and
DSM250 User’s Manual Page 170 Revision 1.4.2 Figure 191 – Trigger Configuration – Data Unavailable Alert Re-trigger Period – When you accept
®®Re-trigger Period – When you accept an alert, it will change to the “Accepted” state, and annunciators that are sounding for that alert will sto
DSM250 User’s Manual 8.3.7.7.2 Trigger Configuration – Outside Radius Alert Figure 194 - Trigger Configuration – Outside Radius Alert Re-trigge
®®8.3.7.8.1 Trigger Configuration Figure 195 – Trigger Configuration - Inside Radius Alert Re-trigger Period – When you accept an alert, it wi
DSM250 User’s Manual The Outside Radius Alert and the Anchor Alert are very similar. The Anchor Alert is designed to allow the input of relatively
®®Alert Clear Point – The Alert will be cleared when the quality of the GPS fix, as reported by the GPS becomes better than the value specified in
Revision 1.4.2 Page 5 ®® Figure 3 – Gimbal Mounting the DSM250 2.4 Connecting the DSM250 The Maretron DSM250 provides a connection to an NMEA
DSM250 User’s Manual 8.3.7.11.1 Trigger Configuration – Direction Alert Figure 198 – Trigger Configuration - Direction Alert Re-trigger Period –
®®8.3.7.12.1 Trigger Configuration – Time Alert Figure 199 - Alert Editor - Time Alert Alert Time – The alert will become active at the time spe
DSM250 User’s Manual 8.3.10 Remote Annunciators Selecting the Remote Annunciators option will bring up a list of 16 ALM100 devices. If the Annunc
®® The desired option is selected using the Scroll Up and Scroll Down buttons, and then pressing the Enter button again. 8.3.13 Operating Mode An
DSM250 User’s Manual Page 180 Revision 1.4.2 Scroll up and down using the Scroll Up and Scroll Down buttons until the alert that must be dele
®® Revision 1.4.2 Page 181 This brings up the list of Alerts managed by the DSM2590. The following information is shown for each alert that
DSM250 User’s Manual status was transmitted to other Alert Sources that are unmanned, then the warnings would be lost. For this reason, the Vessel
®®8.7.1 Remote Alerts The DSM250 may be set up to not respond to Alerts generated by other devices on the bus. This is a global setting and will a
DSM250 User’s Manual 9 Maintenance Regular maintenance is important to ensure continued proper operation of the Maretron DSM250. Perform the foll
®®Revision 1.4.2 Page 185
DSM250 User’s Manual Page ii Revision 1.4.2 Revision History Rev. Description 1.0 Original document. 1.4.2 Added sections on Alert and Anchor W
DSM250 User’s Manual Page 6 Revision 1.4.2 3 Operating the DSM250 3.1 Turning the DSM250 On To turn on the DSM250, press the power key (the l
DSM250 User’s Manual 10 Troubleshooting If you notice unexpected operation of the Maretron DSM250, follow the troubleshooting procedures in this
®®Revision 1.4.2 Page 187 11 Technical Specifications Specifications Parameter Value Comment NMEA 2000® Standard Level A Highest Level of C
DSM250 User’s Manual Page 188 Revision 1.4.2 Wind Apparent & True Wind Direction and Speed, Ground Referenced Speed and Direction NMEA 20
®®Revision 1.4.2 Page 189 130576 Small Craft Status N/A Electrical Parameter Value Comment Operating Voltage 9 to 16 Volts DC Voltage Po
DSM250 User’s Manual Page 190 Revision 1.4.2
®®Revision 1.4.2 Page 191 12 Technical Support If you require technical support for Maretron products, you can reach us in any of the followin
DSM250 User’s Manual Page 192 Revision 1.4.2
®®Revision 1.4.2 Page 193 13 Installation Template Please check the dimensions before using the following diagram as a template for drilling t
DSM250 User’s Manual Page 194 Revision 1.4.2 Figure 201 – Flush Mounting Template
®®Revision 1.4.2 Page 195
®® Figure 6 – Powerdown Countdown Screen 3.3 Keypad Essentials The DSM250 has a five-key keypad located below the screen. Each key has slightly d
DSM250 User’s Manual 14 Maretron (2 Year) Limited Warranty Maretron warrants the DSM250 to be free from defects in materials and workmanship for
®®To apply for warranty claims, contact Maretron or one of its dealers to describe the problem and determine the appropriate course of action. If
DSM250 User’s Manual Power Key ( ) – turns the DSM250 off (see Section 3.1 on page 6 for details). Back Key ( ) – returns to the next higher-level
®® Figure 8 – Entering a Textual Value The top line contains the textual string that has already been entered. New characters are appended one at
DSM250 User’s Manual To abort the entire textual edit, and return to the original field without changing the contents of the field, use the Scrol
Revision 1.4.2 Page 11 ®®4 Important Concepts 4.1 Favorite Screens The DSM250 can display many different types of information in many differe
DSM250 User’s Manual Average L-N Voltage – displays average line to neutral RMS voltage of the AC power on the generator Average L-L Voltage – dis
®®an Alert is triggered. The Anchor Watch display shows the last reported position of the vessel relative to the reported Anchor Drop position and
DSM250 User’s Manual Page 14 Revision 1.4.2 Heat Index – displays the current heat index based on air temperature and humidity Humidity Inside
®®4.2.9 Fuel Management WARNING: Maretron fuel management products are designed to be accurate and reliable; however they should be used only as a
Revision 1.4.2 Page iii ®®Table of Contents 1 General ...
DSM250 User’s Manual Page 16 Revision 1.4.2 Lat/Lon – displays the current latitude and longitude of the vessel Speed Over Ground – displays th
®®Revision 1.4.2 Page 17 4.2.16 Speed Speed Through Water – displays the speed of the boat relative to the water Speed Over Ground - displays
DSM250 User’s Manual Page 18 Revision 1.4.2 4.2.18 Temperature The DSM supports the display of temperatures. Each temperature sender on the bu
®®Revision 1.4.2 Page 19 Trim Tabs – displays the position of the vessel’s trim tabs 4.2.22 Wind Dir. Apparent – displays the angle of the win
DSM250 User’s Manual Page 20 Revision 1.4.2 4.3 Alerts An alert is a signal to a user that there is either an alarm or warning condition requi
®®Revision 1.4.2 Page 21 • Disabled – All alerts are disabled. This mode should be used when the vessel is in storage, dry-dock, or otherwise
DSM250 User’s Manual Page 22 Revision 1.4.2 4.3.5 Alert States Alerts exist in one of five states. • Disabled - A Disabled Alert is an alarm o
®®Revision 1.4.2 Page 23 • Off Alert – The alert will become active if the monitored switch or flag becomes “OFF” for longer than the time spe
DSM250 User’s Manual Page 24 Revision 1.4.2 5 Operating Modes The DSM250 has two main operating modes including normal viewing of information
®®In menu mode, the DSM250 may be configured by scrolling up and down the menu and selecting one of the submenus found there. The DSM250 Main Menu
DSM250 User’s Manual Page iv Revision 1.4.2 4.3 Alerts ...
DSM250 User’s Manual 5.2.1 Alert Setup Menu Selecting Alert Setup… from the Main Menu allows you to create, delete, and edit the Alerts stored in
®® Figure 12 – Device Selection Screen The “NA” column of the menu displays the node address the device is using. The “Manufacturer” column of th
DSM250 User’s Manual Figure 13 – DSM250 Display Settings Screen 5.2.4.1 Advanced Configuration Advanced Configuration changes some complex para
®®would be the display of ground relative wind. In this case, the wind measured by the weather station needs to be combined with the vessel headin
DSM250 User’s Manual Figure 16 – DSM250 Advanced Information Screen Most of the items within the Advanced Information… menu are obvious and not
®®5.2.4.3 Backlight The DSM250 has three user-programmable lighting levels which may be cycled through using the Lights key ( ) on the keypad whi
DSM250 User’s Manual Figure 19 – Color Palette Selection Screen Use the Scroll Up ( ) or Scroll Down ( ) keys to move the highlight to the color
®®“On”. The background will switch to black and the percentage color settings are now used to define the foreground color. 5.2.4.5 Demo Mode The
DSM250 User’s Manual Figure 22 – Setting the Keyboard Beep Option 5.2.4.7 Label Each DSM250 can be given a software label. Normally this label w
®®5.2.5 Favorite Screens Mode The DSM250 supports two methods of operation in favorites mode: “Auto”, in which the DSM250 automatically cycles th
Revision 1.4.2 Page v ®®6.6.8 Label ...
DSM250 User’s Manual Figure 26 –Favorite Screen Parameters 5.2.6.1 Favorite Mode This entry allows you to select in which display method of favo
®®• 2 Qtrs – Half Bottom – three parameters will be displayed, the first occupying the upper left hand corner of the screen, the second occupying
DSM250 User’s Manual 5.2.6.4 Window Data The Window Data section of the menu allows you to select a particular type of data to be displayed in e
®®Revision 1.4.2 Page 39 data item, but may include any of the following (see Section 7 for descriptions of the available display types). • A
DSM250 User’s Manual 5.2.7 Units Menu The Units Menu allows you to set the desired display units for the DSM250. The following sections provide mo
®®Revision 1.4.2 Page 41 • Statute Miles 5.2.7.4 Boat Speed This menu item allows you to select the units to be used for the display of all bo
DSM250 User’s Manual Page 42 Revision 1.4.2 • Millimeters Mercury (mm Hg) • kPa 5.2.7.9 Fluid Pressure This menu item allows you to select th
®®Revision 1.4.2 Page 43 6 Device Configuration The “Device Configuration…” menu enables you to configure certain types of devices on the NMEA
DSM250 User’s Manual Maretron Ultrasonic Wind and Weather Station (WSO100) – set installation offset, set wind damping rates, and enable/disable i
®®6.1 Bennett EP-30 (NMEA1) Trim Tabs Configuration This describes the configuration of the Bennett EP-30 trim tabs firmware version 1.0.7 (“NMEA
DSM250 User’s Manual Page vi Revision 1.4.2 6.12.3 Instance ...
DSM250 User’s Manual Figure 35 –EP-30 Intermediate Calibration Screen After you have lowered both trim tabs to their full down position and a fe
®®6.2 Maretron ACM100 Configuration This describes the configuration of the Maretron ACM100 firmware version 1.0.6. Figure 37 – ACM100 Configu
DSM250 User’s Manual Page 48 Revision 1.4.2 • Inverse Install • Normal Install Use the Scroll Up and Scroll Down buttons to select the corr
®®6.2.1.6 Installation Description This entry allows you to modify the NMEA 2000 installation description text strings. You can enter any inform
DSM250 User’s Manual Page 50 Revision 1.4.2 • Single-Phase (Phase A, B) – use this value when power is connected via two hot wires (180° out o
®® Figure 40 – Reset Total Energy Recorded Confirmation Screen Press Accept to reset the value, or Cancel to return to the previous screen. Re
DSM250 User’s Manual 6.3 Maretron ALM100 Configuration This describes the configuration of the Maretron ACM100 firmware version 1.0.5. Figure
®®installed, for later reference. Tools such as Maretron N2KAnalyzer allow you to view these values later. See section 3.3.4 for details on how t
DSM250 User’s Manual Page 54 Revision 1.4.2 6.3.4 Test Annunciator The Annunciator may be tested by scrolling the cursor to highlight this entr
®®6.4 Maretron DCM100 Configuration This describes the configuration of the Maretron ACM100 firmware version 1.0.4. Figure 44 – DCM100 Configu
Revision 1.4.2 Page vii ®®6.21.5 Barometric Pressure ...
DSM250 User’s Manual • 600A – A 600 Amp Current Transducer is connected to the DCM100. This has the part number LEMHTA600-S. Select the required
®®6.4.1.5 Restore Factory Defaults This option restores all settings on the device to their factory default state. 6.4.2 Current Sensor Zero Offs
DSM250 User’s Manual Page 58 Revision 1.4.2 6.4.3 DC Type You can configure the DCM100 as to what type of DC power source it is monitoring. Wit
®®Revision 1.4.2 Page 59 6.4.3.6 Charge Efficiency Factor The Charge Efficiency Factor for the battery can be set to a value between 5% and 1
DSM250 User’s Manual Page 60 Revision 1.4.2 6.4.4 Instance This entry allows you to program the NMEA 2000 device instance for the unit. You us
®®6.5 Maretron DSM200 Configuration You can use the DSM250 to configure other remotely-located DSM200 units by using the Remote DSM200 configurat
DSM250 User’s Manual The “NA” column of the menu displays the node address the device is using. The “Manuf.” column of the menu displays the manuf
®®6.6 Maretron DSM250 Configuration You can use the DSM250 to configure other remotely-located DSM250 units by using the Remote DSM250 configurat
DSM250 User’s Manual Figure 52 – DSM250 Remote Device Selection Screen The “NA” column of the menu displays the node address the device is using.
®®6.6.3 Copy device selection from local display Since it is normally desirable for all DSM250 units on a network to display the same sensors, it
DSM250 User’s Manual Page viii Revision 1.4.2 11 Technical Specifications ...
DSM250 User’s Manual Figure 55 – DSM250 Copy favorite settings from local display By selecting this menu item and pressing Enter, all the favor
®® 6.6.7 Copy all settings from local display This is the single operation that makes it easy to have multiple DSM250 displays on a boat. Set one
DSM250 User’s Manual 6.6.9 Remote Device Selection Page 68 Revision 1.4.2
®®6.7 Maretron DST100 Configuration The DSM250 is capable of configuring Maretron’s DST100 for several different parameters including trip log re
DSM250 User’s Manual 6.7.1.2 Installation Description This entry allows you to modify the NMEA 2000 installation description text strings. You c
®®speed calibration process provides a method for the actual STW reading produced by the DST100 to be adjusted within the DSM250 (i.e., calibratio
DSM250 User’s Manual “Reset” menu item is selected will complete the operation. Resetting the trip log zeroes the DST100’s trip log such that all
®®6.8 Maretron EMS100 Configuration This describes the configuration of the Maretron EMS100 firmware version 1.2. The EMS100 is configured to ma
DSM250 User’s Manual • No Gauge – select this option if there is no boost pressure gauge present. • YANMAR Select the required option using th
®®Revision 1.4.2 Page 75 6.8.7 Drive Trim Sender Offset Often, the characteristics of individual drive trim senders vary from their specified
Revision 1.4.2 Page vi ®®Table of Figures Figure 1 – Surface Mounting the DSM250 ...
DSM250 User’s Manual Page 76 Revision 1.4.2 you must select the correct type of gauge for this setting in order for the data to be displayed co
®®Revision 1.4.2 Page 77 with the number of flywheel teeth or alternator pulses per revolution for the engine to which the EMS100 is connected.
DSM250 User’s Manual Page 78 Revision 1.4.2 6.9 Maretron GPS100 Configuration This describes the configuration of the Maretron GPS100 firmware
®®6.9.1.1 Device Instance The Device Instance will be used to identify the GPS100 device on the network. Unless there are multiple GPSs on the ne
DSM250 User’s Manual Page 80 Revision 1.4.2 Figure 66 – Configuring Satellite Elevation Mask on a GPS100 The allowable values for Elevation M
®®the value to “-“) will cause the GPS100 to report any position fixes obtained, regardless of the accuracy of the fix. 6.9.1.5 SNR Mask The DSM2
DSM250 User’s Manual Figure 69 – GPS100 NMEA 2000® PGN Enable/Disable Screen Page 82 Revision 1.4.2 You can enable or disable specific transm
®®causes the screen shown in Figure 71 to be displayed. This will cause the GPS100 to discard all position and satellite data and compute a positi
DSM250 User’s Manual 6.9.4 Device Label A label may be assigned to the GPS100 as an aid to identifying the device over the network. Typically this
®®6.10 Maretron J2K100 Configuration This describes the configuration of the Maretron J2K100 firmware version 1.0.7. The DSM250 is capable of con